Diagram
Inputs: select a blue symbol to edit Results: red-orange values and lines
Shear, moment and deflection diagrams
How to use this calculation
- Enter bore and rod diameter.
- Use supply and back pressure at the cylinder, plus loss force.
- Compare the different extension and retraction areas.
Formula and applicability
A₁ = πD²/4, A₂ = π(D²−d²)/4, Fext = pA₁−pbA₂−Floss, Fret = pA₂−pbA₁−Floss
Quasi-static double-acting single-rod cylinder. For each direction p is the supplied chamber and pb the exhausting chamber. Both are gauge pressures relative to the same ambient pressure. Loss is a positive resisting-force magnitude. A positive thrust difference does not establish manufacturer load ratio, speed, cushion, buckling, side-load, pressure-transient or holding suitability. Air flow and stroke time are not calculated.
Displayed values are rounded. Diagrams illustrate the calculation conditions. Initial material and fluid properties are examples; replace them with values for the actual material, temperature and conditions.
ReferenceUsing this information as a reference
Equations assume particular loads, supports and deformation ranges. Check inputs, units and the applicability of each equation. Diagrams explain conditions; they are not manufacturing drawings or proof of safety.
Material values are typical values or reference ranges, not certified product properties or ready-to-use design allowables. They vary with standards, product form, dimensions, temper and temperature. Check the specifications and inspection certificates for the actual product.
Displayed safety factors and checks apply only to the supplied inputs and calculation model. They do not automatically establish the safety of a complete design, including code compliance, service life, fatigue or joints. For actual design, manufacture and use, separately verify applicable regulations and standards, product specifications, and the necessary tests and engineering review.